TM 10-4610-232-34
VIEW F
Figure 2-24. Wire Run Connections (sheet 1 of 2)
f. Install twelve cable harnesses (14) as follows:
(1) Place gasket (19) on cable harness (14) and insert wires from cable harness (14) through the appropriate hole
in control panel.
(2) Secure cable harness (14) using four screws (15), nuts (16) and Iockwashers (17) and washers (18).
(3) Connect wires from cable harness (14) as tagged and secure wires with tie wraps as required.
g. Install three wires from cable (10) through elbow (13) and secure elbow (13) with conduit nut (12).
h. Connect three wires (8T-4, 8T-5 and 8T-6) from cable (10) at motor starter (11), being careful to connect as tagged
during removal.
i. Install four wires from cable (6) through elbow (9) and secure elbow (9) with conduit nut (8).
j. Connect three wires (8T-1, 8T-2 and 8T-3) of cable (6) at motor starter (7) and the ground connection of cable (6) at
ground strap (3). Secure with tie wraps as required.
k. Install four wires from cable (1) through elbow (5) and secure elbow (5) with conduit nut (4).
l. Connect three wires (L-1, L-2 and L-3) of cable (1) at the top of main circuit breaker (2), being sure to connect as
tagged during removal, Then, connect the ground connection of cable (1) at ground strap (3).
2-117