TM 10-4610-232-34
Figure 2-31. Testing Ground Fault Indicator
ADJUST.
Adjustment of the motor starter resets is as follows (refer to Figure 2-31.1).
NOTE
Length is measured from inside panel door to outside of contactor face.
a.
To shorten, rotate threaded bushing (4) counterclockwise, then rotate threaded shaft (5) counterclockwise to
match length in Table 2-2.
b.
To extend, rotate threaded bushing (4) clockwise, then rotate threaded shaft (5) clockwise until correct dimension
is met as shown in Table 2-2.
Table 2-2.
Used For
Length ± .25 in. (6.35 mm)
MS1
Compressor
8.00 in. (203 mm)
MS3
Raw Water Pump
7.5 in. (191 mm)
MS8
High
Pressure
Pump
6.00 in. (152 mm)
MS7
Booster Pump
7.25 in. (184 mm)
MS2
Distribution Pump
8.25 in. (210 mm)
Figure 2-31.1. Reset Mechanism Adjustment
2-132 Change 1