ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR MAINTENANCE PROCEDURES
COLD WEATHER SYSTEM
THIS SECTION COVERS:
Replace, Service
INITIAL SETUP:
Maintenance Level:
Operator/Crew
Tools:
Operator's Tool Kit (BII) (33901161)
References:
Refer to TM 10-4610-309-24P for repair parts information
Personnel Required:
One
Equipment Condition:
TWPS set up for operation
GENERAL:
This work package contains information and instructions for replacing and servicing components in the
Cold Weather System of the TWPS. The procedures covered in this work package include:
Ice Hole Intake Strainer Replacement
Pump Skid Insulating Cover Replacement
Diesel Heater Air Intake Filter Service
Diesel Heater Fan Blade Service
Diesel Heater Spark Plug Service
Diesel Heater Photocell Service
REPLACE
Ice Hole Intake Strainer Replacment:
Part:
Ice hole intake strainer (TM 10-610-309-24P)
Equipment condition:
Ice hole intake strainer taken out of service
Inspect the ice hole intake strainer for damage that can prevent it from functioning properly and replace if
necessary.
0044 00-1