ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0066 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
GENERAL MAINTENANCE
d. Repeat a, b, and c for the other pipe end. One side must be pushed far enough on to
allow the pipe joint to clear the other pipe end.
e. Fit the pipe joint onto one pipe end. Move the pipes back into alignment.
f. Slide the assemblies at both ends up to the pipe joint so that both gaskets fit up against
the flanges of the pipe joint.
g. Position the clamps over the pipe joint flanges and gasket retainers and secure loosely
with a bolt and nut. When both are installed loosely, tighten the bolt and nut on both
clamps.
h. Tighten the pipe connections and pipe support clamps that were loosened to move the
pipes.
i. Spray the gasket retainers and clamps with the corrosion preventive compound.
j. Run the unit and check the joint for leaks.
Sanitary Clamp Replacement:
Parts (TM 10-4610-309-24P):
Sanitary Clamp
Sanitary Clamp Gasket
Materials:
Clean, dry lint-free rags (WP 0079, Table 1, item 33)
Valve Seal Lubricant (WP 0079, Table 1, item 26)
Equipment Condition:
TWPS in Standby Shutdown with Drain-Down
Replace a sanitary clamp and gasket as follows (see Figure 18):
1. Make sure the TWPS is in Standby Shutdown with Drain-Down. Refer to WP 0017.
2. Remove the sanitary clamp as follows:
a. Unscrew the wing nut.
b. Lift the wing nut out of the notch in the clamp.
c. Open and remove the clamp and gasket from the pipe ends.
3. Clean the pipe end flanges with a clean, lint-free rag and inspect the piping and pipe flange
connections for rust, corrosion and damage that would prevent the sanitary clamp from sealing.
4. Install the sanitary clamp as follows:
a. Apply a little valve seal lubricant to the gasket and insert it between the two pipe ends.
b. Open the new sanitary clamp and place it around the pipe end flanges and gasket.
c. Flip the wing nut over and insert it in the notch in the clamp.
d. Tighten the wing nut. Use a screwdriver in the slot to tighten. Tap with the hammer all
around and tighten again.
e. Run the unit and check the joint for leaks.
GASKET
SANITARY CLAMP
Figure 18. Sanitary Clamp and Gasket Replacement.
0066 00-19