TM 10-4610-310-14
0009 00
SETUP - continued
15. Connect a section of hose (yellow) from the fitting on the fabric filtrate tank outlet O1 to the suction fitting of
the backwash pump. See Figure 1,Figure 5 and 8.
16. Connect a section of hose (yellow) from the backwash pump discharge fitting to the backwash inlet on the
UF module. See Figure 1,Figure 4 and Figure 8.
17. Connect one end of the high-pressure hose (braided steel) from the COEI box to the high-pressure module
outlet. Tighten securely. See Figure 1 and Figure 9.
HP INLET
(Q)
HP OUTLET
(R)
Figure 9. High-Pressure Pump Module Outlet Connection.
18. Connect the other end of high-pressure hose (braided steel) to the RO module inlet. Tighten securely. See
Figure 10.
RO REJECT
VALVE (V11)
RUPTURE
DISC (RD2)
RO INLET (S)
Figure 10. RO Module High-Pressure Inlet Hose Connection.