TM 10-4610-310-14
0045 00
SAMPLE VALVE INSTALLATION
1. Apply anti-seize tape to sample valve threads.
2. Reinstall the sample valve into end cap. See Figure 8.
SAMPLE
VALVE
(7 PLACES)
NUTS
Figure 8. Sample Valve Installation.
3. Make sure to orient the sample valve to align with piping. Tighten securely. See Figure 2.
4. Reconnect all the sample valve piping. Tighten nuts securely.
6. Disconnect the two outlet hoses, reject (red) and product (white), from the RO module.
7. Start LWP up.
8. Operate RO element module for 15 minutes to flush the system.
SIMULATOR
The simulators are only used for storage, shipping, training, and test of the titanium pressure vessels RO1
through RO7. These RO simulators enable the users to simulate realistic operation of the LWP. Some examples
are simulating seawater operation while using fresh water or for cases where using actual RO membranes are
undesirable as in training sessions.
The simulator is installed in the end cap at the sampling valve end of the RO pressure vessels. There are two
types; one has a drilled hole and six without.