TM 10-4610-310-14
0046 00
CONTROL PANEL
WARNING
When checking for voltage on an energized component, extreme care must be taken. Only qualified and
authorized electrician should maintain, troubleshoot, and operate energized equipment. Injury or death to
personnel may result.
Opening
1. Open the control panel by turning the switch (2) to OFF position. See Figure 2.
2. Loosen and slide the eight Latches off the control panel. See Figure 1.
3. Hold the panel closed with one hand to allow the switch (2) to rotate. Keep the hand on the panel.
4. Turn the safety tab (1) clockwise with the other hand. Do not let go of the safety tab (1).
5. Turn the switch (2) counter-clockwise. The safety tab (1) and the switch (2) should be squeezed
together.
6. Open the control panel. Ensure that none of the latches slid back into position.
Figure 2. Circuit Breaker.