TM 10-4610-310-14
0099 00
REMOVAL- continued
5. Loosen the setscrew (2) on the throttle arm (1). See Figure 2.
6. Remove cable by loosening lower lock nut (4) on throttle plate (3) and rotating outer sleeve (5) counter-
clockwise.
Figure 2. High-Pressure Pump Module Throttle Location.
INSTALLATION
Push the throttle cable through the throttle plate (3) and set screw (2). See Figure 2.
1.
Screw the throttle cable outer sleeve (5) into the throttle plate (3).
2.
Tighten the lower lock nut (4).
3.
Refer to Figure 1 for the remaining steps.
4.
Install the adjustment mechanism on the module by tightening the retaining nut and washer.
5.
Connect the throttle cable onto the adjusting mechanism.
6.
Tighten the cable sleeve retaining nut on the throttle cable.
7.
Ensure that the cable is pushed all the way in.
8.
Tighten the cable retaining setscrew on the cable.
9.
END OF WORK PACKAGE