TM 10-4610-310-14
0104 00
INSPECTION
Check Valve
1. Inspect the check valve (2) (See Figure 3) by shaking it back and forth. The ball inside should slide freely.
2. Inspect the o-rings on the check valve to ensure they are serviceable.
3. The check valve should permit flow of fluid in only one direction. The direction of the flow is marked on
the body of the check valve.
Y-Strainer
1. Inspect the Y-strainer by removing the cap and check the screen inside. See Figure 10.
2. Ensure that the strainer is clean. Install the retainer end first.
RETAINER
SCREEN
CAP
Figure 10. Y-Strainer.
INSTALLATION
Before installation, the following tasks must be completed.
1. Clean all threads from old anti-seize tapes.
2. Wrap all male threads with four wraps of anti-seize tapes.
3. Ensure that all O-rings on the unions and check valves are serviceable.
CAUTION
Care must be taken not to cross thread piping. Never over tighten. Damage to equipment may result.
4. All plastic fitting must be hand tightened plus a quarter more turn using the strap wrench provided.