TM 10-4610-310-14
0105 00
Totalizer
1.
Remove nuts (6) and washers (7) and remove U-bolts (3). See Figure 2.
2.
Loosen union (5) all the way.
3.
Remove the totalizer (4). Remove union (5) from totalizer (4) if necessary.
4.
Remove dust plug (1), female camlock (2), and adapter (8) if necessary.
Figure 2. Totalizer.
INSTALLATION
Thermometer
1. Apply anti-seize tape to thermometer threads.
2. Install thermometer (2) onto thermowell fitting (1). See Figure 1.
3. Install thermowell fitting (1) in the cleaning tank if necessary.
Totalizer
1.
Apply anti-seize tape to all threaded connection.
2.
Install adapter (8), female camlock (2) and dust plug (1).
3.
Install union (5) on the totalizer (4) if necessary.
4.
Install totalizer (4) on the module. Tighten union (5).
5.
Install U-bolt (3) and secure with nuts (6) and washers (7).
END OF WORK PACKAGE