TM 10-4610-310-14
UNIT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
CHEMICAL MODULE
GAUGES
REMOVAL/INSTALLATION
INITIAL SETUP
Tools
Equipment Condition Required
All equipment de-energized. Hoses disconnected from
Tool Kit, General Mechanics, Automotive
chemical module. All switches in off position
Material/Parts
Thermometer, 2-inch, (PN 30-EI-60-E-040-
20/120F)
GENERAL
This work package contains information and instructions for the removal and installation of the temperature gauge
on the chemical module used on the Lightweight Water Purifier (LWP). The thermometer measures the
temperature of the solution in the cleaning tank T4 during the flushing of membranes and various cleaning tasks.
REMOVAL
Temperature Gauge
Cleaning tank thermometer (2) is located on the side of the cleaning tank. See Figure 1.
1.
SOME
DETAILS
OMITTED FOR
CLARITY
Figure 1. Cleaning Tank Thermometer.
Unthread the temperature gauge (2) from thermowell fitting (1).
2.
Remove thermowell fitting (2) only if necessary.
3.