TM 10-4610-310-14
0118 00
INSPECTION
1. Inspect the O-ring (2) and the gasket (4) for serviceability.
2. Inspect the electrical connector for corrosion. Replace if necessary.
3. Measure the resistance across the coil.
b. Measure the resistance across the two spade terminals (facing each other). Not the ground (top
flat prong) (See Figure 1). It should read between 108 and 132 Ohms. Replace the coil other
wise.
ASSEMBLY
1. Refer to figure 1 for this procedure section.
2. Connect the wires to the electrical connector (5) if needed.
3. Connect the electrical connector (5) and gasket (4) to the coil (3).
4. Slide the coil (3) on to the shaft on the valve (7).
5. Secure the coil with cap nut (1) and O-ring (2).
END OF WORK PACKAGE