TM 10-4610-229-24
3-29. ALTERNATOR REPAIR (CONT)
11
Remove field diode assembly retaining nut.
12
Using heat dam and soldering iron, desolder three wires.
NOTE
If any diode is defective, replace entire field diode assembly.
13
Using multimeter, check continuity from each lead (one at a time) to terminal stud. Continuity should be in one
direction only and all leads should rive same reading.
NOTE
Readings other than 0 indicate open windings. Replace stator if test indicates open windings.
14
Using multimeter, check continuity from terminal A to B on stator. Reading should be 0.
3-59