3-49. ALTERNATOR REPAIR (CONT)
2
Connect one multimeter lead to one field coil lead.
3
Connect other multimeter lead to other field coil lead. If multimeter reading is high (infinity), field coil is open.
Replace field coil.
4
Install rear cover. Install four washers and bolts.
e.
Disassembly
1
Remove four bolts and washers. Remove rear cover.