TM 10-4610-232-34
C. Refer to Figure 2-26 and disassemble four selector switches as follows:
(1) Open control panel door.
(2) Tag and disconnect electrical wires from switch (3).
(3) Unscrew nut on knob (1), remove Iockwasher (2) and remove switch (3) and washers (4) from the panel.
Figure 2-26. Upper Exterior Panel, Selector Switches
d. Refer to Figure 2-27 and disassemble three flowmeters as follows:
(1) Open control panel door.
(2) Remove terminal board cover (1). The cover snaps onto the terminal board on the rear of flowmeter (4).
(3) Tag and disconnect electrical wires from the terminal board on the flowmeters.
(4) Loosen two mounting screws (2) and remove bracket (3) with jack screws (6).
(5) Remove flowmeter (4) through the front of the control panel.
(6) If necessary, remove pads (5) which are glued to the flowmeter.
WASTE
Figure 2-27. Upper Exterior Panel, Flowmeters
FLOW
2-121