TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
NOTE
All receptacle connectors in the control box and junction box assemblies are
removed the same. One receptacle connector is shown as typical.
a. Remove cap (1) from receptacle connector (2).
NOTE
If working on junction box assembly, go to step d.
b. To remove receptacle connector located in the control box assembly (3), remove 14 screws (4),
lockwashers (5), and flat washers (6).
c.
Lower control box cover (7) and go to step e.
d. To remove receptacle connector from the junction box assembly (8), turn 1.3 rotary fasteners (9) and
lower junction box cover (10).
e. Remove four nuts (11), lockwashers (12), flat washers (13), and screws (14). Discard lockwashers.
f.
Remove receptacle connector (2) and gasket (15).
NOTE
To unsolder wires from receptacle connectors, it may be necessary to remove
Tag wires with pin connection before unsoldering.
g. Using soldering gun, unsolder wires (16) from recepacle connector (2) and remove receptacle
t
connector.
h. If working on control box assembly, close control box cover (7) and install, but do not tighten 14 screws
INSTALLATION.
NOTE
All receptacle connectors in the control box and junction box assemblies are
removed and installed the same. One receptacle connector is shown as
typical.
Wires must be soldered to pin connections as tagged.
a. If working on control box assembly, remove 14 screws (4), lockw shers (5), and flat washers (6).
a
Lower control box cover (7).
b. Using soldering gun, solder wires (16) to receptacle connector (2).
3-174