TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
a. Turn 13 rotary fasteners (1) and lower junction box cover (2).
NOTE
Tag all wires before removal.
There are five electrical cables connected to terminals in the junction box
assembly. All are removed the same. One is shown.
b. Remove electrical cable (3) from junction box assembly (4). Refer to paragraph 3-38.
NOTE
There are seven cables with connectors which attach to receptacles mounted
on the junction box assembly. All are removed the same. One is shown.
c.
Remove cable connector (5) from receptacle (6).
d. Remove nut (7), lockwasher (8), flat washer (9), and wire lug (10) from ground stud (11). Discard
lockwasher.
e. Remove four screws (12) and flat washers (13) from standoffs (14).
f.
Tilt circuit breaker plate (15) forward to access mounting hardware.
g. Remove three nuts (16), lockwashers (17), and screws (18). Discard lockwashers.
h. Position circuit breaker plate (15) on standoffs (14) and install four screws (12) and flat washers (13).
WARNING
The junction box assembly is heavy/difficult to handle. Two people are needed
to support/lift it to prevent personal injury or damage to the equipment.
i.
Support junction box assembly (4) and remove nine nuts (19), lockwashers (20), and screws (21).
Discard lockwashers.
j.
Close junction box cover (2) and turn 13 rotary fasteners (1).
k.
Remove junction box assembly (4).
3-184