ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0007 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
SET-UP OPERATION UNDER USUAL CONDITIONS
CAUTION
The high pressure pump mounting flange drain tube must be positioned lower than
the flange and must be free of obstructions so that the tube drains freely. Failure
to observe this caution may result in water accumulating in the flange, which can
lead to pump shaft and bearing corrosion and failure.
4. Check that the HP pump mounting flange drain tube is directed off the TWPS and is free of any
obstructions.
a. The drain tube on the MC-TWPS extends to the edge of the TWPS frame (see Figure
11).
b. The drain tube on the A-TWPS is slightly longer so that the end can be directed down
between the right edge of the deck and the fabric wall.
HPP MOUNTING FLANGE
HPP MOUNTING FLANGE DRAIN TUBE
Figure 11. High Pressure Pump Mounting Flange Drain Tube.
NOTE
For the most efficient use of time, it is recommended that you proceed to WP 0013
for pre-operational diagnostic self-tests and then the appropriate start-up
procedures WP before performing the Fabric Wall Set-Up and Extended
Distribution System Set-Up procedures below. You will be instructed to return to
these two procedures after performing the electrical pre-operational procedures
and the appropriate start-up procedures.
0007 00-19