TACTICAL WATER PURIFICATION SYSTEM (TWPS)
PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS
SET-UP OPERATION UNDER USUAL CONDITIONS
FABRIC WALL SET-UP (A-TWPS)
After the TWPS is running and producing product water and delivering it to the product water distribution
tanks, set up the fabric wall as follows (see Figure 12):
1. Unfold the fabric wall and lay it on the ground oriented as follows:
a. The outside of the wall on the ground and the inside of the wall facing up.
b. The bottom of the zippered, roll-up door closest to the TWPS.
c. The 3 in. hose feed-through opposite the raw water inlet of the TWPS.
d. The 4 in. hose feed-through opposite the waste water outlet of the TWPS.
e. The straps laid out for easy access.
PIN
FOOTMAN LOOP
STRAP
TOP PANEL
TIE CORD
SUPPORT LEG
Figure 12. Fabric Wall Set-Up (A-TWPS).
WARNING
Potential for head injury. Hold the top panel while removing the pins from the top
panel supports. Failure to do so could result serious head injuries.
2. Two people carefully remove the pins from the top panel supports and lower the top panel to
about a 45 angle with about 18 in. of the supports extended. Insert the pins to hold this position.