TM 10-4610-310-14
0039 00
CHEMICAL CLEANING PROCEDURE - continued
4. Attach cleaning outlet hose from BII to UF filtrate bypass valve (See Figure 5). Place the plastic
bucket from the BII box under the hose to catch the bypass flow.
FILTRATE BYPASS
VALVE
CLEANING OUTLET
HOSE (FROM BII BOX)
Figure 5. Ultrafiltration Module.
5. Ensure that Circuit Breaker CB 1 is in OFF position. Disconnect booster pump cable from control
module.
6. Disconnect backwash pump cable from control module.
7. Connect backwash pump cable to booster pump receptacle on control module.
NOTE
The switching of the cable is done to allow the use of a single pump while ensuring correct solenoid valve
opening.
8. Cap all the unused electrical connections.