TM 10-4610-310-14
0039 00
CHEMICAL CLEANING PROCEDURE - continued
2. Perform product water flush procedure. See WP 0013 00.
CAUTION
All hose connections must be clean. Dirt or debris may be ingested into the piping system. Failure to
follow this precaution may render the solenoid valves on the UF module inoperable. Failure to follow this
precaution may result in damage to equipment
3. Reconnect hoses according to (steps a-i).
1
Cleaning Tank Outlet
2
UF Inlet
3
UF Reject
4
Cleaning Tank Inlet
Figure 2. Ultrafiltration Cleaning Piping Diagram.
a. Close the outlet spool piece on the settling tank.
b. Drain filtrate tank by disconnecting one inlet and two outlet hoses at the base of the filtrate tank.
See Figure 3 for location.
c.
Drain the membrane cartridges by opening the five drain valves on the UF module.
d. Once drained, install the caps onto both outlet connections on the filtrate bag. Close the drain
valves.
e. Cap the filtrate tank inlet hose. See Figure 3 for location.