TM 10-4610-310-14
0039 00
CHEMICAL CLEANING PROCEDURE continued
CAUTION
Do not allow the immersion heater element to contact the side of the tank.
9. Remove the immersion heater from the COEI box. Loosen wing nut on bracket. Turn bracket
approximately 90 degrees. Tighten wing nut.
10. Hang heater over the module frame and into the cleaning tank. Use bracket to support the
immersion heater on the side of tank. See Figure 6.
11. Attach heater plug to receptacle J9 on control module.
CAUTION
Ensure that the booster and raw water pumps are switched off before turning on the immersion
heater for cleaning. The electrical system will draw too many amperes and may trip the 3kW
TQG set circuit breaker. Damage to equipment may result.
12. Place the Circuit Breaker CB-1 in the ON position
13. Place HEATER selector switch on the control module in the ON position.
14. Allow water to heat to 100F (Never exceed 110 F). Turn the heater off when 100F is reached.
Monitor the built in thermometer for water temperature.
CLEANING
IMMERSION HEATER
TANK T4
BRACKET
WINGNUT
MODULE FRAME
Figure 6. Immersion Heater with Bracket.