TM 10-4610-310-14
OPERATOR MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
ULTRAFILTRATION MEMBRANE CHEMICAL CLEANING
INITIAL SETUP
Materials/Parts
Special Environmental Conditions
Do not allow drainage to be contaminated
Equipment Status
LWP set up for normal operations
Tools
Water in product tank is needed
Paddle, stirring, (PN 3485K14)
Immersion heater, 2000-watt, (PN 2850332001)
Chlorine Test Strip (481126-50)
GENERAL
This work package contains information and instructions to chemically clean the three ultrafiltration (UF)
membranes in the UF module used in the Lightweight Water Purifier (LWP). The UF module will be chemically
cleaned when the UF differential pressure exceeds 30 psi.
The cleaning may consist of up to three chemicals, each followed by a clean water rinse. The chemicals are
M334, M331, and citric acid.
CHEMICAL CLEANING PROCEDURE
CAUTION
To avoid damage to the LWP, make sure cleaning tank is clean and free of dirt, trash, and
debris before starting.
1. Release the two latches on cleaning tank. Lift up cover. Use gray sampling hose to fill the cleaning
tank to the bottom of the cleaning tank inlet. Open 3-way Valve to fill. See Figure 1.
CLEANING TANK INLET
3-WAY VALVE
CLEANING
TANK
SAMPLING
HOSE
PRODUCT WATER INLET
Figure 1. Filling Cleaning Tank.