TM 10-4610-310-14
0086 00
FILTRATE TANK PIPING
1. Disconnect the vent hose (1), level switch hose (4) and inlet hose (5).
Figure 2. Filtrate Tank Piping.
2. Remove male camlock fittings (3), tee fitting (6), and adapter (7) only if necessary.
3. Remove dust plugs (2) and dust caps (8) only if necessary.
INSTALLATION
Before installation, ensure all hoses and fittings are clean and serviceable.
1. Install the adapter (7), and tee fitting (6) and male camlock fittings (3) on the filtrate tank if necessary.
2. Connect the inlet hose (5), level switch hose (4), and vent hose (1).
3. Install the dust plugs (2) and dust caps (8) if necessary.
END OF WORK PACKAGE
0086 00-2