TM 10-4610-310-14
UNIT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
FILTRATE TANK
REMOVAL/INSTALLATION
initial setup
Tools
Personnel Required
Tool Kit, LWP (PN 3600486000)
2
Material/Parts
Equipment Condition Required
Rags, cotton, A-A-531
All equipment de-energized.
Tank, Filtrate (PN 3300367001)
All hoses from the UF module disconnected
GENERAL
This work package contains information and instructions for the removal and installation of the filtrate storage
tank and inlet/outlet piping in the Ultrafiltration (UF) module used on the Lightweight Water Purifier (LWP). The
tank capacity is 40 gallons.
FABRIC FILTRATE TANK
REMOVAL
1. Ensure that the filtrate tank (1) is drained. Remove the straps from the module frame. See Figure 1.
TANK
STRAPS
Figure 1. UF Filtrate Tank.
2. Disconnect the backwash hose and HP pump feed hose if necessary.
3. Remove the eight straps from the frame.