TM 5-3800-205-10-2
TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE
1. Check fuel tank gage with key
1. If indication is empty, add fuel
1.
Engine Cranks But Fails to Start
start switch on.
(Operating Temperature Above 32F
Maintenance if gage is
(0C).
inoperative. Go to test step 2 if
gage is okay.
2. If fuse is bad, request a
2. Check for blown fuel pump
replacement fuse from Unit
fuse at fuse/circuit breaker
Maintenance. If fuse is good,
panel in cab.
go to test step 3.
3. Open fuel shutoff valve(s) as
3. Check that fuel shutoff
required. If problem still
valve(s) located on fuel tank
exists, go to test step 4.
are fully OPEN.
WARNING
If machine is parked indoors, DO NOT run engine unless exhaust fumes are vented to the outside.
Failure to follow this warning may cause injury or death due to carbon monoxide poisoning.
4. If problem still exists after
4. Place air intake preheat switch
thirty (30) seconds with switch
ON, notify Unit Maintenance.
1. Check fuel tank gage with key
1. If indication is empty, add fuel
2.
Engine Cranks But Fails to Start
start switch on.
(Operating Temperature Below 32F
Maintenance if gage is
(0C).
inoperative. Got to test step 2
if gage is okay.
2. If fuse is bad, request a
2. Check for blown fuel pump
replacement fuse from Unit
fuse at fuse/circuit breaker
Maintenance. If fuse is good,
panel in cab.
and problem still exists, go to
test step 3.
3. Open fuel shutoff valve(s) as
3. Check that fuel shutoff
required. If problem still
valve(s) located on fuel tank
exists,
notify
Unit
are fully OPEN.
Maintenance.