TM 5-3800-205-10-2
TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
2.
Engine Cranks But Fails to Start
(Operating Temperature Below 32F
(0C) - Continued.
WARNING
If machine is parked indoors, DO NOT run engine unless exhaust fumes are vented to the outside.
Failure to follow this warning may cause injury or death due to carbon monoxide poisoning.
NOTE
For every 30 seconds of engine cranking, allow two (2) minutes for starter motor to cool down.
4. If engine still will not start,
4. While cranking engine, press
notify Unit Maintenance.
top of ether start aid switch.
Wait approximately two (2)
seconds between injections.
3.
Engine Does Not Develop Full Power.
Check air filter service indicator.
1. If indicator is red, clean air
If problem still exists, notify
Unit Maintenance.
4.
Engine Does Not Idle Properly.
Check air filter service indicator.
1. If indicator is red, clean air
If problem still exists, notify
Unit Maintenance.
5.
Engine Fails to Crank When Key Start
1. Check position of battery
1. Place battery disconnect
disconnect switch.
switch to ON. If problem still
Switch is Turned to Start.
exists, go to test step 2.
2. Check position of transmission
2. Place transmission shift lever
shift lever.
in N (Neutral). If problem still
exists, go to test step 3.
NOTE
A thirty (30) minute cool down time may be required before circuit breaker can be reset.
3. Check that key start switch
3. Reset circuit breaker. If
circuit breaker is not tripped.
problem still exists, go to test
step 4.
4. Check for dirty, loose or
4. Clean dirty cables. Tighten
damaged battery cables.
loose connections. If cable is
damaged,
notify
Unit
Maintenance.