Remove second R.O. element from sealed plastic bag.
(8) Install brine seal (1) into groove of second R.O. element. Make sure that the open end of the brine
seal is opposite the direction of flow.
(9)
Refer now to figure 3-8. Insert product water tube (2) of the second R.O. element into interconnector (3).
FIGURE 3-8. ELEMENT REPLACEMENT
(10) Refer now to figure 3-9. Slide both R.O. elements (1) and interconnector (2) into R.O. vessel (3) until
they are centered in the vessel.
(11) Place end connectors (4) on both ends of product water tubes of R.O. elements. Join them to product
water tubes of end caps.
FIGURE 3-9. ELEMENT REPLACEMENT