3-54. INJECTION PUMP REPLACEMENT (CONT)
4
With governor control lever in shutoff position, place spacer over rod that makes contact with rack.
5
Put force on rod that makes contact with rack, to hold spacer in position while dial indicator setting is made.
6
Place dial indicator on zero. Take spacer away from rod that makes contact with rack.
7
Using circuit tester, connect clip end to brass terminal on governor housing.
8
Place other end of tester on good ground.
8
Turn governor lever in FUEL-ON direction until test light comes on.
9
Move governor lever toward SHUT-OFF position until test light goes out.