ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0028 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
PREPARATION FOR MOVEMENT ARMY UNIT
19. At the rear of the skid, secure the RO element pusher to the horizontal pipe to the left of the MF
filters using two 18-in. hook and loop straps (see Figure 20).
HOOK AND LOOP STRAPS
ELEMENT PUSHER
Figure 20. Filtrate Drain/Sample Hose and RO Element Pusher Packout.
1. Raise and secure the bail bar as follows:
a. Connect the cable to the bail bar.
b. Turn the winch crank handle to raise the bail bar.
NOTE
Installing the two large bolts, lockwashers, and nuts at the bottom of the bail bar
first helps align the holes for the other bolts and makes the other bolts easier to
install.
c.
Install the two large bolts, lock washers, and nuts that secure the bottom of the bail bar to
the flat rack (see Figure 21).
WARNING
A minimum of 6 bolts in the front of top horizontal beam of the flat rack and a
minimum of 3 bolts in the underside of the top horizontal beam are required in
order to safely lift the flat rack by the bail bar. Failure to observe this warning may
result in equipment damage and severe injury or death.
CAUTION
The middle and upper bail bar bolts must be installed in their proper locations to
ensure that the bail bar is properly secured. There are three different length bolts
that are used. The longest of the three is used with washers and nuts to secure
the bail bar to the diagonal beam of the flat rack. The other two shorter bolts
thread into rivet nuts, which are threaded inserts that are welded in the top
horizontal beam of the flat rack.
0028 00-31