ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0028 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
PREPARATION FOR MOVEMENT ARMY UNIT
d. Separate the three different size bolts that are used to secure the middle of the bail bar to
the diagonal beam of the flat rack and the top of the bail bar to the top horizontal flat rack
beam (see Figure 21).
e. Loosely secure the top part of the bail bar to the front of the top horizontal flat rack beam
using the seven short bolts with their lock washers and flat washers. Do NOT tighten yet.
f. Loosely secure the top part of the bail bar to the underside of the top horizontal flat rack
beam using the four longer bolts with their lock washers and flat washers. Do NOT
tighten yet.
g. Secure the middle of the bail bar to the diagonal flat rack beams using the four longest
bolts with eight flat washers, four lock washers, and four nuts.
h. Tighten all 15 bolts. Torque to 250 in-lbs.
TOP HORIZONTAL FLAT RACK BEAM
SHORT BOLT
LONGER BOLT
LONGEST BOLT
DIAGONAL
FLAT RACK BEAM
LOCK WASHER
PINCH BAR
BOLT
NUT
BAIL BAR SOCKET WRENCH
Figure 21. Correct Bail Bar Bolt Installation Locations.
0028 00-32