TM 10-4610-310-14
0007 00
LOADING THE TRICON continued
WARNING
The collapsible fabric tanks are to be lifted by at least two personnel. Failure to observe this
precaution may result in serious personal injury.
13. Place the settling tank on top of the service pump skid. See Figure 2.
14. Place the product tank on top of the settling tank.
WARNING
The 3kW TQG set weighs 304 pounds. At least six personnel are required to move the 3kW
TQG set. Serious injury to personnel and/or damage to equipment could result.
15. Connect straps (4 and 5) on the D rings located on the floor immediately in front of the service pump module.
These straps will be used to secure the TQG, COEI and CWK1 boxes. See Figure 4.
16. Place the 3kW TQG set on the hand truck with the fuel fill cap forward. Secure with tie-down strap. See
Figure 3.
HAND TRUCK
TIE-DOWN STRAP
Figure 3. Loading 3kW Tactical Quiet Generator Set on Hand Truck.
17. Load the 3kW TQG set to the front left side of the TRICON. See Figure 4.
18. Place the hand truck on top of the UF module. Ensure that the blade is facing down.
19. Place the hoses on top of the hand truck and the product tank. All the fabric hoses should be in COEI box.