TM 10-4610-310-14
0085 00
UF REJECT OUTLET PIPING
2. Remove male camlock (5) and dust cover (6) only if necessary. See Figure 9.
FAST FLUSH MANIFOLD PIPING
1. Loosen the unions (3) and (2) to remove this piping. Remove drain valve (1) only if necessary. See
Figure 10.
Figure 10. Fast Flush Manifold Piping.
FAST FLUSH PIPING
All three fast flush piping are interchangeable.
1. Remove the coil from the solenoid valve. See WP 0088 00.
2. Loosen the unions (1,2,6). Remove the coil from the solenoid valve. See WP 0088 00.
Figure 11. Fast Flush Piping.
3. Remove screws (3), lock washers (4) and washers (5) from solenoid valve support. See Figure 11.