TM 10-4610-310-14
UNIT MAINTENANCE
LIGHTWEIGHT WATER PURIFIER
SETTLING AND PRODUCT TANKS
FILLER/DISCHARGE FITTINGS
REMOVAL/REPAIR/INSTALLATION
INITIAL SETUP
Materials/Parts
General Safety Conditions
Gasket, 2-inch (5.1 cm) (PN MS27030-6)
Observe all CAUTIONS and WARNINGS
Cleaning solvent, dry, (MIL-PRF-680, Type II)
Equipment Condition Required
Tank has been drained
Coupling, filler, female, 2-inch, (PN 01000722, 01000385
Plug, dust, PN 01000381)
Coupling, discharge, male, 2-inch, (PN 01000722, 01000384
Cap, dust, PN 01000382)
GENERAL
This work package contains information and instructions to remove, repair, and install the filler/discharge fittings
used on the product and settling collapsible fabric tanks in the Lightweight Water Purifier (LWP). The filler fitting
has a dust plug; the discharge fitting has a dust cap.
REMOVAL
Filler Fitting
1. Pull cam-lever arms on female quick disconnect out, away from body of coupling and remove dust plug from
coupling.
2. Unthread the female coupling from the adapter. See Figure 1.
3. Unthread adapter and nipple from the tank if necessary.
4. Remove eight bolts and remove the bulkhead fitting from the tank if necessary.
TANK
BOLT (8)
ADAPTER
DUST
PLUG
BULKHEAD FITTING
NIPPLE
FEMALE QUICK
DISCONNECT
Figure 1. Settling and Product Tank Filler Fitting.