TM 10-4610-310-14
0108 00
REMOVAL - continued
Discharge Fitting
1. Remove dust cap from quick disconnect.
2. Unthread the male quick disconnect from the bulkhead fitting if necessary.
3. Remove eight bolts and remove the bulkhead fitting from the tank if necessary. See Figure 2.
BOLT (8)
MALE QUICK DISCONNECT
TANK
DUST CAP
BULKHEAD FITTING
Figure 2. Settling and Product Tank Discharge Fitting.
INSTALLATION
Filler Fitting
1. Install the bulkhead fitting and secure with bolts. See Figure 1.
2. Install the nipple and the adapter if necessary.
3. Install the female quick disconnect on the adapter.
4. Install dust plug in female quick disconnect.
Discharge Fitting
1. Install the bulkhead fitting and secure with bolts. See Figure 2.
2. Install the male quick disconnect.
3. Install dust cap onto end of coupling.
Emergency Repair
If the settling tank is ruptured beyond repair, connect raw water pump discharge to UF inlet. Plug raw water
pump into booster pump connector on panel. Pump water directly into the UF module for operation.
If the settling tank spool pieces are damaged and no spares are available, drape raw water pump discharge hose
directly into the top of the settling tank. Or pump directly into the UF module as in the step above.
END OF WORK PACKAGE